| IP Number | First Digit - SOLIDS | Second Digit - LIQUIDS | 
| IP00 | Not protected from solids. | Not protected from liquids. | 
| IP01 | Not protected from solids. | Protected from condensation. | 
| IP02 | Not protected from solids. | Protected from water spray less than 15 degrees from vertical. | 
| IP03 | Not protected from solids. | Protected from water spray less than 60 degrees from vertical. | 
| IP04 | Not protected from solids. | Protected from water spray from any direction. | 
| IP05 | Not protected from solids. | Protected from low pressure water jets from any direction. | 
| IP06 | Not protected from solids. | Protected from high pressure water jets from any direction. | 
| IP07 | Not protected from solids. | Protected from immersion between 15 centimeters and 1 meter in depth. | 
| IP08 | Not protected from solids. | Protected from long term immersion up to a specified pressure. | 
| IP10 | Protected from touch by hands greater than 50 millimetres. | Not protected from liquids. | 
| IP11 | Protected from touch by hands greater than 50 millimetres. | Protected from condensation. | 
| IP12 | Protected from touch by hands greater than 50 millimetres. | Protected from water spray less than 15 degrees from vertical. | 
| IP13 | Protected from touch by hands greater than 50 millimetres. | Protected from water spray less than 60 degrees from vertical. | 
| IP14 | Protected from touch by hands greater than 50 millimetres. | Protected from water spray from any direction. | 
| IP15 | Protected from touch by hands greater than 50 millimetres. | Protected from low pressure water jets from any direction. | 
| IP16 | Protected from touch by hands greater than 50 millimetres. | Protected from high pressure water jets from any direction. | 
| IP17 | Protected from touch by hands greater than 50 millimetres. | Protected from immersion between 15 centimeters and 1 meter in depth. | 
| IP18 | Protected from touch by hands greater than 50 millimetres. | Protected from long term immersion up to a specified pressure. | 
| IP20 | Protected from touch by fingers and objects greater than 12 millimetres. | Not protected from liquids. | 
| IP21 | Protected from touch by fingers and objects greater than 12 millimetres. | Protected from condensation. | 
| IP22 | Protected from touch by fingers and objects greater than 12 millimetres. | Protected from water spray less than 15 degrees from vertical. | 
| IP23 | Protected from touch by fingers and objects greater than 12 millimetres. | Protected from water spray less than 60 degrees from vertical. | 
| IP24 | Protected from touch by fingers and objects greater than 12 millimetres. | Protected from water spray from any direction. | 
| IP25 | Protected from touch by fingers and objects greater than 12 millimetres. | Protected from low pressure water jets from any direction. | 
| IP26 | Protected from touch by fingers and objects greater than 12 millimetres. | Protected from high pressure water jets from any direction. | 
| IP27 | Protected from touch by fingers and objects greater than 12 millimetres. | Protected from immersion between 15 centimeters and 1 meter in depth. | 
| IP28 | Protected from touch by fingers and objects greater than 12 millimetres. | Protected from long term immersion up to a specified pressure. | 
| IP30 | Protected from tools and wires greater than 2.5 millimetres. | Not protected from liquids. | 
| IP31 | Protected from tools and wires greater than 2.5 millimetres. | Protected from condensation. | 
| IP32 | Protected from tools and wires greater than 2.5 millimetres. | Protected from water spray less than 15 degrees from vertical. | 
| IP33 | Protected from tools and wires greater than 2.5 millimetres. | Protected from water spray less than 60 degrees from vertical. | 
| IP34 | Protected from tools and wires greater than 2.5 millimetres. | Protected from water spray from any direction. | 
| IP35 | Protected from tools and wires greater than 2.5 millimetres. | Protected from low pressure water jets from any direction. | 
| IP36 | Protected from tools and wires greater than 2.5 millimetres. | Protected from high pressure water jets from any direction. | 
| IP37 | Protected from tools and wires greater than 2.5 millimetres. | Protected from immersion between 15 centimeters and 1 meter in depth. | 
| IP38 | Protected from tools and wires greater than 2.5 millimetres. | Protected from long term immersion up to a specified pressure. | 
| IP40 | Protected from tools and small wires greater than 1 millimetre. | Not protected from liquids. | 
| IP41 | Protected from tools and small wires greater than 1 millimetre. | Protected from condensation. | 
| IP42 | Protected from tools and small wires greater than 1 millimetre. | Protected from water spray less than 15 degrees from vertical. | 
| IP43 | Protected from tools and small wires greater than 1 millimetre. | Protected from water spray less than 60 degrees from vertical. | 
| IP44 | Protected from tools and small wires greater than 1 millimetre. | Protected from water spray from any direction. | 
| IP45 | Protected from tools and small wires greater than 1 millimetre. | Protected from low pressure water jets from any direction. | 
| IP46 | Protected from tools and small wires greater than 1 millimetre. | Protected from high pressure water jets from any direction. | 
| IP47 | Protected from tools and small wires greater than 1 millimetre. | Protected from immersion between 15 centimeters and 1 meter in depth. | 
| IP48 | Protected from tools and small wires greater than 1 millimetre. | Protected from long term immersion up to a specified pressure. | 
| IP50 | Protected from limited dust ingress. | Not protected from liquids. | 
| IP51 | Protected from limited dust ingress. | Protected from condensation. | 
| IP52 | Protected from limited dust ingress. | Protected from water spray less than 15 degrees from vertical. | 
| IP53 | Protected from limited dust ingress. | Protected from water spray less than 60 degrees from vertical. | 
| IP54 | Protected from limited dust ingress. | Protected from water spray from any direction. | 
| IP55 | Protected from limited dust ingress. | Protected from low pressure water jets from any direction. | 
| IP56 | Protected from limited dust ingress. | Protected from high pressure water jets from any direction. | 
| IP57 | Protected from limited dust ingress. | Protected from immersion between 15 centimeters and 1 meter in depth. | 
| IP58 | Protected from limited dust ingress. | Protected from long term immersion up to a specified pressure. | 
| IP60 | Protected from total dust ingress. | Not protected from liquids. | 
| IP61 | Protected from total dust ingress. | Protected from condensation. | 
| IP62 | Protected from total dust ingress. | Protected from water spray less than 15 degrees from vertical. | 
| IP63 | Protected from total dust ingress. | Protected from water spray less than 60 degrees from vertical. | 
| IP64 | Protected from total dust ingress. | Protected from water spray from any direction. | 
| IP65 | Protected from total dust ingress. | Protected from low pressure water jets from any direction. | 
| IP66 | Protected from total dust ingress. | Protected from high pressure water jets from any direction. | 
| IP67 | Protected from total dust ingress. | Protected from immersion between 15 centimeters and 1 meter in depth. | 
| IP68 | Protected from total dust ingress. | Protected from long term immersion up to a specified pressure. | 
| IP69K | Protected from total dust ingress. | Protected from steam-jet cleaning. |